Data Acquisition Interface (9062)
LVDAM®-EMS 3.0 displays twice the voltage that is input to the Data Acquisition Interface 9062-1X.
Release Date: 2006/04/26
Affected Model(s): LVDAM®-EMS 3.0 and later versions
Affected Product(s): 9062-1X
Brief Description of the Problem:
LVDAM®-EMS 3.0 displays twice the voltage that is input to the Data Acquisition Interface, Lab-Volt Model 9062-1X.
Full Description of the Problem:
The problem occurs when a Data Acquisition Interface, Model 9062-1X, from the first productions is used with a version of LVDAM®-EMS that is higher than 2.1r2. The problem is due to the fact that the Data Acquisition Interfaces from the first productions do not provide LVDAM®-EMS with the information about the variant of the unit (120/208 V - 60 Hz or 220/380 V - 50 Hz). This causes LVDAM®-EMS to "see" all units as 220/380 V - 50 Hz variants and explains why the displayed voltage is twice the actual value.
How to Fix:
A minor modification is required in the Data Acquisition Interface, Model 9062-1X, to fix the problem. Please, download the following pdf file which contains a detailed step-by-step procedure that explains how to modify the Data Acquisition Interface.
Download pf1057.pdf
Unable to open the Data Table window.
Release Date: 04-05-06
Affected Model(s): 9481, 9407, 9062
Affected Product(s): LVSIM-DCOM, LVDAM-COM, LVDAM-EMS
Brief Description of the Problem:
Unable to open the Data Table window.
Full Description of the Problem:
The Data Table window cannot be opened in any one of the aforementioned Lab-Volt software products. In certain situations, this may cause the software from which the attempt to open the Data Table window is performed to close.
How to Fix:
Download and run the self extracting files which will install the files needed to open the Data Table window without any problem.
Download pf1049.exe




